Configuring BLE sensors on Suntech devices
Pair Minew BLE sensors with Suntech GPS devices and show the values in Navixy. Covers BeaconSET+ and MSensor setup, SyncTrak pairing and report mapping, and the BLE event codes for panic, door, and th
Bluetooth Low Energy (BLE) sensors let you monitor temperature, humidity, door state, and panic events without extra wiring. A Suntech GPS device with a BLE gateway scans those sensors and sends the values to Navixy inside its normal status and alert reports.
This article covers BLE sensors: how to prepare Minew beacons, how to pair them in SyncTrak, and how to show the data in Navixy. For ignition and digital inputs, see Mapping the ignition motion input for Suntech devices in Navixy.
Compatible Suntech families (BLE gateway required):
ST4300 series, for example ST4315B, ST4345LB
ST4900 series, for example ST4932, ST4955LCBW, ST4915LCBF
ST8000 series, for example SD8000U, ST8230
Confirm BLE support and the matching Navixy model for your exact device before you start. The parameter examples below come from an ST4315B. Slot numbers can differ on other models if Report Mapping uses a different field order.
How to prepare the sensors in the Minew apps
The device only reads what each sensor already broadcasts. Configure the sensor first. Write down the MAC address of every sensor. You need it in SyncTrak.
Install BeaconSET+ for the wristband and the temperature and humidity sensor. Install MSensor for the door sensor. Enable Bluetooth, open the app, and select the sensor by MAC address.
Sensor setup via mobile apps
Minew B10 wristband (panic button): Use BeaconSET+ app (default PIN: minew123 or 000000)
Slot 1 iBeacon: Base params OFF.
Trigger Params: ON. Enable tap types (single, double, triple).
Trigger type: Enable single, double, and triple tap if the app offers them.
Advertising time after the trigger: 10 seconds. With 1 second, the button often stops before the device scans, and the panic event is lost.
Interval & Power: 900 ms, 0 dBm.
The device reports panic as event 136. The subtype follows the number of clicks:
One click: Packet 136;1 (Navixy sub_event_code: 136_1)
Two clicks: Packet 136;2 (Navixy sub_event_code: 136_2)
Three clicks: Packet 136;3 (Navixy sub_event_code: 136_3)
Minew temperature & humidity sensor: Use BeaconSET+ (default PIN: minew123)
Slot 1 iBeacon: Base params OFF (iBeacon alone carries no telemetry).
Telemetry Slot (SLOT4 TLM / HT): Base params ON.
Interval & Power: 900–1000 ms, 0 dBm.
Minew S4 door sensor: Use MSensor (default PIN: minewtech1234567)
Operating Mode: Regular mode (Don't use Energy-saving mode, or door events are delayed/dropped).
Interval & Power: 900–1000 ms, 0 dBm.
How to pair the sensors in SyncTrak
After the sensors start broadcasting, open the SyncTrak desktop tool to configure the BLE scanning rules of the device.
BLE Parameter tab
BLE SCAN (4021): Enable.
Sensor RPT BLE scan time (4011): 20 seconds.
Continuous scan (4037): Enable. Keep Continuous scan enabled when you use a panic button or a door sensor. If you disable it, the BLE receiver sleeps between scan windows. A press or a door change in that window is dropped. Temperature and humidity can still update.
BDA RPT BLE scan time (4012): Set lower than Fine Tracking time. If the scan lasts longer than the report interval, the device aborts the scan to send the report on time. The BLE report then shows scan status 0 and sensor count 0.
Register BLE tab
Add the wristband and the climate sensor here. Sensor type: 5: MINEW. Click ADD, enter the MAC address, and save.
The registration order matters. The first sensor is dedicated BLE 1, the second is dedicated BLE 2. Report fields such as
DED_BLE1_TEMPfollow that order. Keep the order stable.Set In alert to Enable only when you use the high and low thresholds of that sensor. Don't register the door sensor only on this tab.
Register Door tab
Register the door sensor here. Sensor type: 4: MINEW DOOR. Enable door sensor for that point.
The firmware keeps door peripherals in a separate list. A door sensor that exists only under Register BLE sends no door state. The same MAC can appear on both tabs without harm, but Register Door is the entry that works.
BLE Sensor Config tab
Set BLE sensor report (2610) to Stt/Alt scan enable so BLE values attach to standard reports.

Enable BLE alerts in SyncTrak
On the alert configuration tabs, enable the events you use in Navixy:
119: Dedicated BLE sensor in range
120: Dedicated BLE sensor out of range
121 / 122: Dedicated BLE temperature high / low
124 / 125: Dedicated BLE humidity high / low
135: Dedicated BLE door state
136: Dedicated BLE panic state
Report Mapping tab
Navixy doesn't read the raw BDA BLE report. Select the BLE fields in Report Mapping so they travel inside STT and ALT.
Select at least:
Temperature and humidity of the dedicated climate sensor (for example
DED_BLE1_TEMPandDED_BLE1_HUM, orDED_BLE2_*if that sensor is point 2).Large ID of the dedicated BLE sensor if you want the MAC in the Navixy platform.
Note the position of each field in the S_ASSIGN column, listed in the Small Table box on the right of the screen. The first field in that column arrives as stt_small_assign_1, the second as stt_small_assign_2, and so on.
On one ST4315B lab object with several S_ASSIGN fields selected (voltage, altitude, then BLE measurements), temperature arrived as stt_small_assign_6 and humidity as stt_small_assign_7. If you select fewer fields, or a different order, the slot numbers change. Always confirm the slot in Air Console. Once the sensors are mapped, see Monitor sensor values for how the readings appear in Navixy.
How data reaches Navixy and platform setup
Register the GPS device in Navixy using the matching device model.

How the device communicates
The device transmits three main packet types:
STT is the periodic status report. It carries mapped BLE measurements on every Fine Tracking interval.
ALT is the alert report. The device sends it when panic, door, or threshold events occur. Mapped BLE fields are included on that packet too.
BDA is a separate BLE dump. Navixy doesn't process it. Keep the fields in Report Mapping.
How to show the BLE data in Navixy
In Navixy, register the device under the device model.
Go to Devices > Sensors and buttons.
Open Air Console to inspect incoming parameters:
Input Bitmask: Read right-to-left. Bit 0 = Ignition, Bit 1 = Input 1, Bit 2 = Input 2. (00000001 = Ignition ON; 00000011 = Ignition ON + Input 1 grounded, using motion ignition).
Output Bitmask: Bit 0 = Output 1, Bit 1 = Output 2 (00000011 = both active).
Create Measuring Sensors: Map
stt_small_assign_6to Temperature (°C) andstt_small_assign_7to Custom / Humidity (%).

How to create rules and alerts for BLE events in Navixy
Navixy processes hardware events via event_code and sub_event_code. For the alert rule types that consume them, see Inputs and outputs.
Panic events (event_code 136)
136_1: Single click
136_2: Double click
136_3: Triple click
Cooldown limit: The device firmware enforces a 60-second cooldown per click type. A second single click within 60 seconds is dropped, but a double click can still trigger immediately.
Door state (event_code 135)
135_0: Door closed (135;0;6,MAC)
135_1: Door opened (135;1;6,MAC)
Sensor range alerts
119: Dedicated BLE sensor in range
120: Dedicated BLE sensor out of range
121 / 122: BLE temperature high / low
124 / 125: BLE humidity high / low
Rule setup tip: Trigger on event_code when any press or door activity must generate the alert. Trigger on sub_event_code, for example 135_1 or 136_3, when filtering for specific states.

Verification and troubleshooting
Panic or door events never arrive? Ensure Continuous scan (4037) is enabled in the BLE Parameter tab.
BLE telemetry empty or zero? Verify Parameter 4012 scan time is shorter than the Fine Tracking report time. Ensure mobile setup apps are fully closed.
Door state missing? Confirm the door sensor MAC is registered under the Register Door tab, not Register BLE.
See also
Manage sensors: add sensors and fix missing readings, wrong units, and measurement gaps
Monitor sensor values: build multi-conditional sensor alerts for cold chain and equipment monitoring
Mapping the ignition motion input for Suntech devices in Navixy: how Suntech physical inputs map to Navixy input channels
Configuring Suntech ST4410G master-slave in Navixy: master-slave redundancy, distance monitoring, and alert integration
Last updated
Was this helpful?