Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.
GuideBeta

Calculating values in several steps

Build an IoT Logic flow through Navixy GraphQL API that calculates values in a chain of nodes: fuel in litres, then percentage and change, then a check.

A flow can calculate a value in one node and use it in the next one. This guide builds a flow for tanker trucks that reads a fuel sensor in three steps. The first node converts the sensor voltage to litres. The second node calculates the fill percentage and the change since the previous message. A logic node then marks a sudden drop as a possible fuel drain.

The guide is for developers who have built a first flow. If you haven't, start with Creating and updating flows, which explains the request format, node keys, and updates.

Prerequisites

You need an access token for the workspace you work in, and the ID of a device that reports a fuel sensor value. See Find the devices for the flow.

You also need the name of the attribute that the fuel sensor reports. The name depends on the device model. The example uses analog_1, the voltage of the first analog input in millivolts. See Find the attribute names of your devices.

Why a chain of nodes

A chain of Initiate Attribute nodes splits one long calculation, written in the Navixy IoT Logic Expression Language, into short steps. It has three advantages over one long expression:

  • Each expression stays short. A condition can have at most 480 characters, and an attribute expression at most 960.

  • Each intermediate value is an attribute of its own, such as fuel_level_l. Later nodes read it by name, and so do the other tools of the Navixy platform once the message reaches an Output Endpoint.

  • A validation error points at one short expression, so it is easier to fix.

Build the chain as one straight path. Don't calculate two values on parallel paths and join them in a later node: paths in a flow never join, and a write with such a graph fails with SIMULTANEOUS_PATHS. To calculate several values from the same input, put them in one node or in consecutive nodes.

Example scenario: Detecting a fuel drain on tanker trucks

To build and check the flow, follow these steps:

1

Create the flow

Send the whole chain in one flowCreate mutation. The query requests the attributes and the condition, so the response confirms what Navixy stored:

mutation CreateFlow($input: IotLogicFlowCreateInput!) {
  iotLogic {
    flowCreate(input: $input) {
      flow {
        id
        version
        isEnabled
        nodes {
          __typename
          id
          name
          ... on IotLogicFlowInitiateAttributesNode {
            attributes {
              name
              expression
            }
          }
          ... on IotLogicFlowLogicNode {
            condition
            expressionName
          }
        }
        transitions {
          from
          to
          type
        }
      }
    }
  }
}

Variables:

{
  "input": {
    "title": "Fuel level and drain detection",
    "description": "Converts the fuel sensor voltage to litres and flags sudden drops.",
    "nodes": [
      {
        "key": "tanks",
        "type": "DATA_SOURCE",
        "name": "Tanker trucks",
        "deviceIds": ["019dbec6-d381-8000-801f-44455643f7c4"],
        "position": { "x": 0, "y": 0 }
      },
      {
        "key": "litres",
        "type": "INITIATE_ATTRIBUTES",
        "name": "Fuel in litres",
        "attributes": [
          { "name": "fuel_level_l", "expression": "(analog_1 - 500) * 0.1" }
        ],
        "position": { "x": 240, "y": 0 }
      },
      {
        "key": "derived",
        "type": "INITIATE_ATTRIBUTES",
        "name": "Percentage and change",
        "attributes": [
          { "name": "fuel_level_pct", "expression": "fuel_level_l / 400 * 100" },
          {
            "name": "fuel_change_l",
            "expression": "fuel_level_l - value('fuel_level_l', 1, 'valid')"
          }
        ],
        "position": { "x": 480, "y": 0 }
      },
      {
        "key": "drain",
        "type": "LOGIC",
        "name": "Sudden drop",
        "condition": "fuel_change_l < -20",
        "expressionName": "is_fuel_drain",
        "position": { "x": 720, "y": 0 }
      },
      {
        "key": "out",
        "type": "OUTPUT_ENDPOINT",
        "name": "Default output",
        "position": { "x": 960, "y": 0 }
      }
    ],
    "transitions": [
      { "from": "tanks", "to": "litres", "type": "SIMPLE" },
      { "from": "litres", "to": "derived", "type": "SIMPLE" },
      { "from": "derived", "to": "drain", "type": "SIMPLE" },
      { "from": "drain", "to": "out", "type": "THEN" },
      { "from": "drain", "to": "out", "type": "ELSE" }
    ]
  }
}

Response:

{
  "data": {
    "iotLogic": {
      "flowCreate": {
        "flow": {
          "id": "01a0d413-9e6c-8000-801f-494c464c237e",
          "version": 1,
          "isEnabled": false,
          "nodes": [
            {
              "__typename": "IotLogicFlowDataSourceNode",
              "id": "01a0d413-9e6b-8000-801f-494c4e449820",
              "name": "Tanker trucks"
            },
            {
              "__typename": "IotLogicFlowInitiateAttributesNode",
              "id": "01a0d413-9e6b-8001-801f-494c4e44c174",
              "name": "Fuel in litres",
              "attributes": [
                { "name": "fuel_level_l", "expression": "(analog_1 - 500) * 0.1" }
              ]
            },
            {
              "__typename": "IotLogicFlowInitiateAttributesNode",
              "id": "01a0d413-9e6b-8002-801f-494c4e44f434",
              "name": "Percentage and change",
              "attributes": [
                { "name": "fuel_level_pct", "expression": "fuel_level_l / 400 * 100" },
                {
                  "name": "fuel_change_l",
                  "expression": "fuel_level_l - value('fuel_level_l', 1, 'valid')"
                }
              ]
            },
            {
              "__typename": "IotLogicFlowLogicNode",
              "id": "01a0d413-9e6b-8003-801f-494c4e444ad0",
              "name": "Sudden drop",
              "condition": "fuel_change_l < -20",
              "expressionName": "is_fuel_drain"
            },
            {
              "__typename": "IotLogicFlowOutputEndpointNode",
              "id": "01a0d413-9e6b-8004-801f-494c4e44cadf",
              "name": "Default output"
            }
          ],
          "transitions": [
            {
              "from": "01a0d413-9e6b-8000-801f-494c4e449820",
              "to": "01a0d413-9e6b-8001-801f-494c4e44c174",
              "type": "SIMPLE"
            },
            {
              "from": "01a0d413-9e6b-8001-801f-494c4e44c174",
              "to": "01a0d413-9e6b-8002-801f-494c4e44f434",
              "type": "SIMPLE"
            },
            {
              "from": "01a0d413-9e6b-8002-801f-494c4e44f434",
              "to": "01a0d413-9e6b-8003-801f-494c4e444ad0",
              "type": "SIMPLE"
            },
            {
              "from": "01a0d413-9e6b-8003-801f-494c4e444ad0",
              "to": "01a0d413-9e6b-8004-801f-494c4e44cadf",
              "type": "THEN"
            },
            {
              "from": "01a0d413-9e6b-8003-801f-494c4e444ad0",
              "to": "01a0d413-9e6b-8004-801f-494c4e44cadf",
              "type": "ELSE"
            }
          ]
        }
      }
    }
  }
}
2

Check how each step reads the previous one

Each node of the chain reads what an earlier node calculated. This table follows one message through the flow:

Node
Reads
Calculates

Fuel in litres

analog_1, which the device sends

fuel_level_l: the voltage above 500 mV, at 0.1 litre per millivolt

Percentage and change

fuel_level_l from the previous node, and the previous valid fuel_level_l from the history of the device

fuel_level_pct for a 400-litre tank, and fuel_change_l since the previous message

Sudden drop

fuel_change_l from the previous node

is_fuel_drain: true when the tank lost more than 20 litres since the previous message

Three details make the chain work:

  • value('fuel_level_l', 1, 'valid') reads the last value of fuel_level_l before the current one, and skips messages that had no value. Navixy keeps the value in the history of the device only because the path ends at an Output Endpoint. On a path that ended anywhere else, the flow would have no previous value to read.

  • The first message of a device has no previous value, so fuel_change_l has no value either. The condition fuel_change_l < -20 then isn't true, and the message leaves by ELSE. is_fuel_drain gets no value for that message. That's the result you want: a first message is never a drain.

  • Both outcomes of the logic node lead to the Output Endpoint. The flow keeps fuel_level_l, fuel_level_pct, and fuel_change_l on every message, not only on the messages that look like a drain.

3

Enable the flow

The flow is created disabled. Enable it with isEnabled: true and the current version, as in Enable the flow. Enabling validates the whole graph again, including the check that no other flow already produces fuel_level_l, fuel_level_pct, fuel_change_l, or is_fuel_drain for the same devices.

4

Check the calculated values

After the trucks send their next messages, read their values with flowDebugValues, as in Checking what a flow calculated. Each message with analog_1 has fuel_level_l and fuel_level_pct. From the second message on, it also has fuel_change_l and is_fuel_drain. Compare fuel_level_l with analog_1 to confirm the conversion, and read nonNullFields to see the previous valid value that fuel_change_l was calculated from.

Extending the chain

To react to a drain, add nodes to the THEN outcome of the logic node, and end the new path at the Output Endpoint, so that the flow still keeps its attributes. For example, put an Initiate Attribute node between the THEN outcome and the Output Endpoint to calculate the size of the drop, fuel_drain_l, only for the messages that look like a drain. The ELSE outcome still leads straight to the Output Endpoint. The two paths can meet there because a message never takes both.

To also send a command to the truck, add a THEN transition to a Device Action node next to the THEN transition that you already have. A Device Action node calculates nothing, so the flow still keeps its attributes. To notify a system outside Navixy about the drain, add one more THEN transition, to a Webhook node with {{fuel_level_l}} in its body. See IF/THEN Logic for the rules of logic node outcomes.

To add a calculation, add an Initiate Attribute node to the chain with an update. The update sends the whole graph, so send the stored nodes with their IDs and the new node with a key only. See Replace the graph.

Errors in this scenario

A chain of calculations most often fails validation for these reasons:

Violation
Cause in a chain
How to fix

INVALID_EXPRESSION

A formula doesn't parse, for example because of an unknown function

Correct the formula. The message names the logic node, or the attribute for an attribute formula, and the position. nodeIds has the node.

SIMULTANEOUS_PATHS

Two values are calculated on parallel paths that join in one node

Put the calculations in one straight chain.

DUPLICATE_ATTRIBUTE_IN_FLOW

Two nodes of the chain calculate an attribute with the same name

Rename one of them.

ATTRIBUTE_ALREADY_PRODUCED

Another flow already calculates the same attribute for one of the devices

Rename the attribute, or remove the device from one of the flows.

For every violation code and the structure of the error, see Flow validation errors.

See also

Last updated

Was this helpful?